Seals | Parker Spool Code | Parker Valve Style Code | Spool Type | Solenoid Voltage | Solenoid Connection | Max Flow (at 3000 PSI) | UOM | Valve Variation |
---|---|---|---|---|---|---|---|---|
Buna-N (Nitrile) | 001 | C | Closed Center - All Ports Blocked | 24 VDC | Conduit | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 001 | C | Closed Center - All Ports Blocked | 24 VDC | Plug-In Conduit Box | 20 GPM (77 LPM) | EACH | Signal Lights |
Buna-N (Nitrile) | 001 | C | Closed Center - All Ports Blocked | 24 VDC | DIN Style (43650) w/o Plug | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 001 | C | Closed Center - All Ports Blocked | 120/60 - 110/50 VAC | Conduit | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 001 | C | Closed Center - All Ports Blocked | 120/60 - 110/50 VAC | Plug-In Conduit Box | 20 GPM (77 LPM) | EACH | Signal Lights |
Buna-N (Nitrile) | 001 | C | Closed Center - All Ports Blocked | 120/60 - 110/50 VAC | DIN Style (43650) w/o Plug | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 004 | C | Float Center - P Blocked, A&B > T | 24 VDC | Conduit | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 004 | C | Float Center - P Blocked, A&B > T | 24 VDC | Plug-In Conduit Box | 20 GPM (77 LPM) | EACH | Signal Lights |
Buna-N (Nitrile) | 004 | C | Float Center - P Blocked, A&B > T | 24 VDC | DIN Style (43650) w/o Plug | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 004 | C | Float Center - P Blocked, A&B > T | 120/60 - 110/50 VAC | Conduit | 20 GPM (77 LPM) | EACH | N/A |
Buna-N (Nitrile) | 004 | C | Float Center - P Blocked, A&B > T | 120/60 - 110/50 VAC | Plug-In Conduit Box | 20 GPM (77 LPM) | EACH | Signal Lights |
Buna-N (Nitrile) | 004 | C | Float Center - P Blocked, A&B > T | 120/60 - 110/50 VAC | DIN Style (43650) w/o Plug | 20 GPM (77 LPM) | EACH | N/A |